2640_picture_582035c90fb191.jpg

 

ExSg112M-4-2GT4_2D

 

logo-cantoni

 

ELECTRICAL PARAMETERS

400

3.7

5.9

50

-

2.4

80.8

3.3

83.3

1.0

83.8

S1

-

4.9

-

1500

0.65

1450

0.77

15.8

0.84

3

-

GENERAL DATA

-

62

112

72

4

top

DOL or Y/∆

yes

F

63062Z

no

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

33

aluminium

0.014

cast iron

CW/CCW

RAL5010

IP66

N

ENVIRONMENTAL CONDITIONS

from -20 up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

2

on demand

3 x PTC

on demand

STANDARDS

EN 60034-1, EN 60079-0, EN 60079-7, EN 60079-15, EN 60079-31

CERTIFICATES

ATEX

ADDITIONAL INFO

II 2G Ex eb IIC T4 Gb / II 2D Ex tb IIIC T125°C Db

ELECTRICAL PARAMETERS

400

3.7

5.9

50

-

2.4

80.8

3.3

83.3

1.0

83.8

S1

-

4.9

-

1500

0.65

1450

0.77

15.8

0.84

3

-

GENERAL DATA

-

62

112

72

4

top

DOL or Y/∆

yes

F

63062Z

no

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

33

aluminium

0.014

cast iron

CW/CCW

RAL5010

IP66

N

ENVIRONMENTAL CONDITIONS

from -20 up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

2

on demand

3 x PTC

on demand

STANDARDS

EN 60034-1, EN 60079-0, EN 60079-7, EN 60079-15, EN 60079-31

CERTIFICATES

ATEX

ADDITIONAL INFO

II 2G Ex eb IIC T4 Gb / II 2D Ex tb IIIC T125°C Db