2640_picture_582035c90fb191.jpg

 

ExSg112M-2-2GT4_2D

 

logo-cantoni

 

ELECTRICAL PARAMETERS

400

3.5

7.95

50

-

2

83.1

2.7

85.4

1.0

85.8

S1

-

3.7

-

3000

0.80

2915

0.87

6.6

0.91

3

-

GENERAL DATA

-

71

112

81

2

top

DOL or Y/∆

yes

F

63062Z

no

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

33

aluminium

0.008

cast iron

CW/CCW

RAL5010

IP66

N

ENVIRONMENTAL CONDITIONS

from -20 up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

2

on demand

3 x PTC

on demand

STANDARDS

EN 60034-1, EN 60079-0, EN 60079-7, EN 60079-15, EN 60079-31

CERTIFICATES

ATEX

ADDITIONAL INFO

II 2G Ex eb IIC T4 Gb / II 2D Ex tb IIIC T125°C Db

ELECTRICAL PARAMETERS

400

3.5

7.95

50

-

2

83.1

2.7

85.4

1.0

85.8

S1

-

3.7

-

3000

0.80

2915

0.87

6.6

0.91

3

-

GENERAL DATA

-

71

112

81

2

top

DOL or Y/∆

yes

F

63062Z

no

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

33

aluminium

0.008

cast iron

CW/CCW

RAL5010

IP66

N

ENVIRONMENTAL CONDITIONS

from -20 up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

2

on demand

3 x PTC

on demand

STANDARDS

EN 60034-1, EN 60079-0, EN 60079-7, EN 60079-15, EN 60079-31

CERTIFICATES

ATEX

ADDITIONAL INFO

II 2G Ex eb IIC T4 Gb / II 2D Ex tb IIIC T125°C Db