2513_picture_58523d861c1a42.jpg

 

3SIE450H4D

 

logo-emit

 

ELECTRICAL PARAMETERS

690

2.5

∆ or Y

7.3

50

-

900

96.0

1200

96.5

1.0

96.5

S1

-

887

-

1500

0.79

1493

0.86

5757

0.88

1.5

-

GENERAL DATA

IE3

84

450

-

4

góra/

direct or VSD

yes

F

6324 C3

yes

NU222 /

IMB3/B35/V1

yes

IC411

cast iron

4620

cast iron

35.4

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

660

2.5

∆ or Y

7.3

50

-

900

96.0

1200

96.5

1.0

96.5

S1

-

927

-

1500

0.79

1493

0.86

5757

0.88

1.5

-

GENERAL DATA

IE3

84

450

-

4

góra/

direct or VSD

yes

F

6324 C3

yes

NU222 /

IMB3/B35/V1

yes

IC411

cast iron

4620

cast iron

35.4

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

690

2.5

∆ or Y

7.3

50

-

900

96.0

1200

96.5

1.0

96.5

S1

-

887

-

1500

0.79

1493

0.86

5757

0.88

1.5

-

GENERAL DATA

IE3

84

450

-

4

góra/

direct or VSD

yes

F

6324 C3

yes

NU222 /

IMB3/B35/V1

yes

IC411

cast iron

4620

cast iron

35.4

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

660

2.5

∆ or Y

7.7

60

-

900

96.0

1200

96.5

1.0

96.5

S1

-

927

-

1800

0.79

1793

0.86

4794

0.88

1.5

-

GENERAL DATA

IE3

-

450

-

4

góra/

direct or VSD

yes

F

6324 C3

yes

NU222 /

IMB3/B35/V1

yes

IC411

cast iron

4620

cast iron

35.4

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

690

2.5

∆ or Y

7.7

60

-

900

96.0

1200

96.5

1.0

96.5

S1

-

887

-

1800

0.79

1793

0.86

4794

0.88

1.5

-

GENERAL DATA

IE3

-

450

-

4

góra/

direct or VSD

yes

F

6324 C3

yes

NU222 /

IMB3/B35/V1

yes

IC411

cast iron

4620

cast iron

35.4

cast iron

according to the order

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

3

2 x Pt100 (1 pc/bearing)

3

on demand

6 x Pt100 (2pcs./phase)

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand