2503_picture_584a83fcaaecc1.jpg

 

Sg112M-4

 

logo-celma

 

ELECTRICAL PARAMETERS

400/690

3.0

∆/Y

6.3

50

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

8.3/4.8

-

1500

0.61

1435

0.75

26.62

0.82

2.6

-

GENERAL DATA

-

62

112

72

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

220/380

3.0

∆/Y

6.3

50

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

15.0/8.7

-

1500

0.61

1435

0.75

26.62

0.82

2.6

-

GENERAL DATA

-

62

112

72

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

230/400

3.0

∆/Y

6.3

50

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

14.4/8.3

-

1500

0.61

1435

0.75

26.62

0.82

2.6

-

GENERAL DATA

-

62

112

72

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

380/660

3.0

∆/Y

6.3

50

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

8.7/5.0

-

1500

0.61

1435

0.75

26.62

0.82

2.6

-

GENERAL DATA

-

62

112

72

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

3.0

∆/Y

6.3

50

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

8.3/4.8

-

1500

0.61

1435

0.75

26.62

0.82

2.6

-

GENERAL DATA

-

62

112

72

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

220/380

3.0

∆/Y

6.3

60

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

15.0/8.7

-

1800

0.61

1722

0.75

21.3

0.82

2.6

-

GENERAL DATA

-

65

112

75

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

230/400

3.0

∆/Y

6.3

60

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

14.4/8.3

-

1800

0.61

1722

0.75

21.3

0.82

2.6

-

GENERAL DATA

-

65

112

75

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

265/460

3.2

∆/Y

6.5

60

-

4.6

85.9

6.17

87.9

1.0

87.2

S1

-

14.0/8.1

-

1800

0.61

1722

0.75

25.51

0.82

2.7

-

GENERAL DATA

-

65

112

75

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

380/660

3.0

∆/Y

6.3

60

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

8.7/5.0

-

1800

0.61

1722

0.75

21.3

0.82

2.6

-

GENERAL DATA

-

65

112

75

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

400/690

3.0

∆/Y

6.3

60

-

4.0

84.0

5.5

85.6

1.0

85.1

S1

-

8.3/4.8

-

1800

0.61

1722

0.75

21.3

0.82

2.6

-

GENERAL DATA

-

65

112

75

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand

ELECTRICAL PARAMETERS

460/795

3.2

∆/Y

6.5

60

-

4.6

85.9

6.17

87.9

1.0

87.2

S1

-

8.1/4.7

-

1800

0.61

1722

0.75

25.51

0.82

2.7

-

GENERAL DATA

-

65

112

75

4

top

DOL or Y/∆

yes

F

63062Z

yes

63062Z

IMB3/B5/B35/B14

no

IC411

aluminium

34

aluminium

0.0118

cast iron

CW/CCW

RAL5010

IP55

N

ENVIRONMENTAL CONDITIONS

up to +40

up to 1000

up to 95

ACCESSORY

6

on demand

1

on demand

on demand

on demand

STANDARDS

IEC 60034-1

CERTIFICATES

on demand